Vsan database commit. You can design multiple SANs with different topologies. Each entry consists of a device pWWN or nWWN assignment along with the dynamic VSAN to be assigned. Collect WWPN or alias names of storage ports to zone Collect fcalias details if you use fcalias database Take a backup of the existing configuration Log in to the Apr 20, 2016 · Create necessary VSANs on the new switch (in this example only vsan 10 needs to be created): vsan database vsan 10 When using enhanced zoning in the existing fabric (VSAN), make sure you enable this on the new switch as well: zone mode enhanced vsan 10 When using smart zoning, make sure you enable this on the new switch as well: Interface-based zoning does not work if interop mode is configured in that VSAN. At this point I need to activate the zoneset with the changes and I have read the command is: zoneset acti VSAN 1, also known as the default VSAN, is typically used for communication, management, or testing purposes. VSAN Configuration VSANs have the following attributes: • VSAN ID—The VSAN ID identifies the VSAN as the default VSAN (VSAN 1), user-defined VSANs (VSAN 2 to 4093), and the isolated VSAN (VSAN 4094). You can assign an alias name and configure an alias member using either the FC ID, fabric port WWN (fWWN), or pWWN values. I have added a new zone to our zoneset. For example, if you activate port security, follow up by disabling auto-learning, and finally commit the changes in the pending database, then the net result of your actions is the same as issuing a port-security activate vsan vsan-id no-auto-learn command. Tip Use the show wwn switch command to retrieve the sWWN. We recommend that you do not use VSAN 1 as your production environment VSAN. We recommend you create production environment VSANs and configure the switches to use those VSANs. •Commit destroys the copy of the zoning database after activation. Once VSANs are created, they may exist in various conditions or states. The zone I created has two FCALIAS attached. 10. • Pending database—Your subsequent device alias configuration changes are stored in the pending database. – The Jul 30, 2025 · Step 1 switch# config terminal (Enters configuration mode) Step 2 switch (config)# vsan database switch (config-vsan-db)# (Configures the database for a VSAN. Cisco NX-OS checks the database during a device FLOGI and obtains the required VSAN details. Switch ports Oct 9, 2024 · To release the session lock on the zoning database on the switches in a VSAN, use the no zone commit vsan command from the switch where the database was initially locked. Modifying the Device Alias Database The device alias feature uses two databases to accept and implement device alias configurations. Apr 14, 2015 · VSANs vsan database (same as VLAN database) vsan x (create vsan) vsan 10 interface fc1/1 (assign vsan to interface – same as ‘switchport access vlan 10’) switchport trunk allowed vsan x switchport trunk allowed vsan add y Sep 6, 2019 · This gives you a complete view of what the device alias database will look like once the commit operation is successful. 1/Zoning A. If you modify the device alias configuration, you need to commit or discard the Jan 4, 2013 · Hello I am new to Fabric Switches. You must do additional configuration if you are using two ISLs with in-order delivery of frames. ago Oct 9, 2024 · DPVM assignment is based on the port world wide name (pWWN) and node world wide name (nWWN). I would like to be able to edit vsan 3 on both Page 284 `fcdomain domain 2 static vsan 1` `fcdomain restart disruptive vsan 1` `fabric-binding database vsan 1` `swwn 11:00:02:01:aa:bb:cc:00 domain 4` `fabric-binding activate vsan 1` `zone default-zone permit vsan 1` `ficon vsan 1` Cisco MDS 9000 Series Fabric Configuration Guide, Release 8. Note By default, all Cisco MDS 9000 Family switches belong to VSAN 1. • State—The administrative state of a VSAN can be configured to an active (default) or suspended state. A set of protocols run over the SAN to handle routing, naming, and zoning. You cannot configure any application-specific parameters for a VSAN before creating the VSAN. •Commit has to be issued to apply the changes. In this case, change the device alias mode only, and then commit that change. This database is global to the whole switch (and fabric) and is not maintained for each VSAN. cfg system:running-config show zoneset active copy Aug 9, 2012 · •The first configuration command on the zoning creates a local copy of that VSAN’s zoning database. Aug 13, 2014 · zone commit vsan 11 show zoneset active clear zone database vsan 11 zone commit vsan 11 show zone show fcalias clear device-alias database device-alias commit show device-alias database exit copy run startup-config ## Then apply your new zoning configuration: ## copy ftp://10. Device Alias Databases The device alias feature uses two databases to accept and implement device alias configurations. • Effective database—The database currently used by the fabric. If you do not provide a sWWN, the software automatically uses the local sWWN. FA ports 1D:04 and 2D:04 are connected SWITCH_A and 3D:04 and 4D:04 connected to SWITCH_B for reduncy on the fabric level. •Commit also releases the fabric wide lock A VSAN is a virtual storage area network (SAN). Aug 8, 2025 · DPVM Device Configuration (Static) The DPVM device configuration consists of a series of device mapping entries. show device-alias session status Purpose: This command provides information about the current or last device alias session, including its status and any errors. In SANs you use the physical links to make these interconnections. Aug 18, 2022 · zone broadcast enable vsan zone clone zone commit vsan zone compact vsan zone confirm-commit enable zone convert smart-zoning zone convert zone zone copy zone default-zone zone gs zone merge-control restrict vsan zone mode enhanced vsan zone name (configuration mode) zone name (zone set configuration submode) zone rename zone rscn address-format port zone smart-zoning enable zone-attribute vsan database vsan 2 interface fc1/1 vsan 2 interface fc1/2 vsan 43 interface fc1/8 vsan 43 interface fc1/9 MDS-9710# show zoneset active vsan 43 zoneset name UCS-Fabric-B vsan 43 zone name UCS-B-VMware-Netapp vsan 43 May 12, 2014 · To forcefully discard the changes to the enhanced zone database and close the vsan session created by another user # no zone commit vsan 3 force If sesson locks rmain on remote swtiches after using no zone commit vsan command, clear the lock on remote switches as below # clear zone lock vsan 2 If VSAN session is locked, how to check who locked it? Oct 10, 2023 · This document describes the PWWN (Port Worldwide Name) zoning and device-alias zoning with SAN (Storage Area Networking) processes. About VSANs A VSAN is a virtual storage area network (SAN). A SAN is a dedicated network that interconnects hosts and storage devices primarily to exchange SCSI traffic. If you modify the device alias configuration, you need to commit or discard the changes as the . Configuring DPVM To release the session lock on the zoning database on the switches in a VSAN, use the no zone commit vsan command from the switch where the database was initially locked. Jun 2, 2017 · I'm having trouble editing a vsan that is ISL'd between switchABC and switchXYZ. Application specific VSAN parameters cannot be configured from this prompt) Step 3 switch (config-vsan-db)# vsan 2 (Creates a VSAN with the specified ID (2) if that VSAN does not exist already) Step 4 switch (config-vsan-db)# vsan 2 name You must create a VSAN for the FC-VI ports and a VSAN for the storage ports on each FC switch in the MetroCluster configuration. Creating and Configuring VSANs To create and configure VSANs, follow these steps: Navigate to the health sub-test: Cluster > Monitor > vSAN > Skyline Health > Hardware Compatibility > vSAN HCL DB up-to-date If the vCenter server can communicate with the Internet, click "Get Latest Version Online". How to do zoning in Cisco MDS SAN switches Pre-requisites to do zoning in Cisco Fabric Collect the VSAN ID details and identify VSAN Collect active zoneset in VSAN. For example, I have vsan 3 with a full zoneset on switchABC, and an empty vsan 3 (no zones, no zoneset) on switchXYZ. (sh zoneset active| inc zoneset) Collect WWPN details of the host. What rookie mistake am I making? EDIT: Found the solution! The missing command was: zone commit vsan <vsan> 6 comments Best Add a Comment cantstop_wontstop • 11 yr. The VSANs should have a unique number and name. Diagram-1 In an existing setup, front end ports of VMax3 array (VMAX1234) are connected to 2 separate SAN Switches. Get information 1) the hardware and software by using CLI command "show version" 2) get HBA pwwn from server or storage administrators [note 1] and create a table VSAN Zone Name Device Type Device pwwn 10 production_zone_1 server (initiator) 20:11:12:13:14:15:16:01 storage (target) 50:11: Aug 20, 2014 · port-security commit vsan 101 Helpful show commands show port-security status show port-security database show port-security database active show port-security database vsan 101 port-security database diff config vsan 101 port-security database diff active vsan 101 show port-security violations show port-security statistics And there you have it! I receive the response: WARNING: Specified zoneset already active and unchanged And running show zone <zone name> vsan <vsan id> doesn't list the wwns I just added. x CISCO MDS Zoning Quick Reference Guide Reference guide for performing the Zoning in CISCO MDS Environment by using Command Line Interface. You can configure a maximum of 16,000 DPVM entries in the DPVM database. •Changes done to the zoning database are done on the copy. A DPVM database contains mapping information for each device pWWN/nWWN assignment and the corresponding VSAN. They are ISL'd across fc1/47 and fc1/15, respectively. A blank commit occurs when you lock the fabric, but do not make any database definition changes, and then perform a commit. This results in the distribution of the effective database of the local switch to all other switches in the fabric. The fabric only has one active zoneset and I have backed up the Fabric. huebxxzlewa1ah725zxdgffsyyu28hurgixnkudfeai8jud